トップページへ/TOP メンバー/MEMBER 研究内容/RESEARCH アクセス/ACCESS リンク/LINK

TOP › RESEARCH › Lab. tour

106th room, No.2 Buildg., Advanced Materials Processing Building

An infrared furnace for the fluidity evaluation of asbestos waste

An infrared furnace for the fluidity evaluation of asbestos waste

Vibration mill

Vibration mill

Mafful furnace

Mafful furnace

Autograph

Maximum tension is 10t. We use for compression and bending test.Autograph

Electric furnace for reduction of iron ore

Electric furnace for reduction of iron oreReduction of iron ore and sinter can be taken place under CO-CO2-H2-N2 gas flow.

Electric furnace for the heat-treatment under controlled atmosphere

Electric furnace for the heat-treatment under controlled atmosphereThe heat-treatment can be taken place under Ar, CO, and vacuum below 1100℃. The reaction tube is made of Inconel 601.

Ultrasonic Mechanical Coating and Armouring (UMCA) equipment

Ultrasonic Mechanical Coating and Armouring (UMCA) equipmentUS27, Viatech Ltd.. Mechanical coating of metal substrates using accelerated balls by high speed ultrasonic vibration is carried out. The ultrasonic frequency is around 20kHz and the maximum electric power is 4kW. By using this equipment, the coating of LaPO4 powder on a SUS substrate to give tolerance of high-temperature oxidation and the coatings of TiN powders on metal substrates for wear resistance have been succeeded.

Vertical vibration coating machine

Vertical vibration coating machineTS-MS-100, Techno Science, Ltd.. Surface treatment and powder coating of metal substrates can be carried out. In this machine, accelerated balls by mechanically vertical vibrations collide with a substrate repeatedly and mechanochemical reactions around substrate surface occur. The maximum frequency and amplitude are 90Hz and 100mm, respectively.

Top of the page

206th room, No.2 Buildg., Advanced Materials Processing Building

Thermal analysis system

Thermal analysis system

New TG-DTA(Thermo-plus Evo)

This TG-DTA, which can be heated at 1500℃, is used for relatively clean sample.New TG-DTA(Thermo-plus Evo)

Old TG-DTA(Thermo-plus)

This TG-DTA is for dust sample.Old TG-DTA(Thermo-plus)

Differential scanning calorimeter

Differential scanning calorimeter

SEM-EDX (Keyence, Real surface view)

SEM-EDX (Keyence, Real surface view)Non-coated sample can be observed.

Gas chromatograph - mass spectrometer

Gas chromatograph - mass spectrometerSaturn 2200, Varian, Inc..By using this ion-trap type GC-MS, qualitative and quantitative analyses of infinitesimal amount (in ppb order) of organic compounds in organic solvents can be carried out. It is also possible to quantify organic compounds in ppt order using the MS-MS mode, in which selected fragment ions are broken and mass spectrometry is conducted again. The GC-MS has been used for the analyses of target and intermediate compounds after ultrasonic degradation.

Gas chromatograph

Gas chromatographGC4000, GL Sciences Inc..The hydrogen flame ionization detector is installed in this gas chromatograph. This type of gas chromatograph has general versatility and its analytical sensitivity is comparatively high.


Top of the page

207th room, No.2 Buildg., Advanced Materials Processing Building

Infrared furnace (small)

Maximum heating temperature is 1623K. The exhaust gas can be measured.Infrared furnace (small)

Micro-Gas chromatograph

The gases as H2, N2, O2, CO, CO2 and so on, can be analyzed every 90 seconds by the optimization of the column conditions.Micro-Gas chromatograph

High-frequency induction furnace

High-frequency induction furnaceMaximum power is 15kW. Now we use for the production of iron foam.

Infrared furnace (Big)

Maximum heating temperature is about 1873K.Infrared furnace (Big)

Optical microscope with digital camera

Optical microscope with digital camera

Automatic polisher

Automatic polisher

Newton press

Newton pressSpecial dice is required. We have three dice with a diameter of 14mm, 20mm, and 32mm.

Fine cutter

Fine cutter

Electric balance

Electric balance


Top of the page

210th room, No.2 Buildg., Advanced Materials Processing Building

Ultrasonic horn

Ultrasonic hornC-7281, Kaijo Corporation.This ultrasonic horn has been used to irradiate strong ultrasound and to degrade hexachrolobenzene adsorbed on the sediment particles. The ultrasonic frequency is fixed to 19.5kHz and the maximum electric power attains to 1200W. The control of atmosphere during experiment is possible.

High speed solvent extraction machine

High speed solvent extraction machineASE-100, Dionex Corporation.Quick extraction of organic compounds adsorbed on solid surfaces or dissolved in aqueous solutions can be carried out by using organic solvents under high-pressure and high-temperature conditions.

Ultrasonic degradation apparatus

Ultrasonic degradation apparatus4021, Kaijo Corporation.The ultrasonic transducer is attached at the bottom of the reaction chamber and can irradiate ultrasound to sample solutions. The ultrasonic frequency can be changed from 28 to 600kHz and the maximum electric power is 200W. This apparatus has been used for the ultrasonic degradation experiments of chrolophenols and chrolobenzens in aqueous solutions.

Sonophotocatalysis apparatus (original)

Sonophotocatalysis apparatus (original)The sonophotocatalytic experiments are carried out by irradiating ultrasound from the bottom of the reaction chamber and ultraviolet light from the inserted mercury lamp. This apparatus has been used mainly for the degradation experiments of sewage sludge.

Spectrophotometer

SpectrophotometerPD-303S, Apel Co., Ltd..This spectrophotometer can quantify concentrations of ions or compounds in aqueous solution, which are in proportion to the light absorbance with specific wavelengths. It has been used for the measurements of the concentrations of phosphate ions (PO43-) in sludge samples after pretreatment and of methylene blue in aqueous solutions after sonophotocatalytic treatment.

Anaerobic digestion apparatus (original)

Anaerobic digestion apparatusAnaerobic digestion of samples in Erlenmeyer flasks which are maintained in anaerobic condition are carried out in keeping the temperature constant by the thermostatic bath. Samples are mixed by the 6 series of magnetic stirrers. This apparatus has been used for the anaerobic digestion of the pretreated sludge samples.

COD meter

COD meterHC-607, Central Kagaku Corporation.Chemical oxygen demand is measured by chemical oxidation of samples with potassium permanganate. The COD meter has been used for the COD measurements of the pretreated sludge samples.

BOD meter

BOD meterBOD Trak, Hack GmbH.Biochemical oxygen demand is measured by quantification of CO2 generation amount during biodegradation of samples by microorganisms in aerobic condition. Samples are mixed by the magnetic stirrers. The BOD meter has been used for the BOD measurements of the pretreated sludge samples.

Top of the page

211th room, No.2 Buildg., Advanced Materials Processing Building

Glove box

It is for the treatment of asbestos wastes.Glove box

Low speed cutter

Low speed cutterRCA-005, Refine Saw Lo, Refinetec Co., Ltd..For the purpose of cross section observation of powder coatings, this cutter has been used to cut the samples slowly and precisely.

Planetary ball mill

Planetary ball millp-7, Fritsch GmbH.The mill pot is moving in rotation and revolution simultaneously and it can enhance grinding efficiency. The maximum revolution speed attains to 700rpm. This machine is often used for mechanochemical treatment.


Top of the page

研究内容/RESEARCH

subject of research Lab. tour